This assay has high sensitivity and excellent specificity for detection of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1).No significant cross-reactivity or interference between Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and analogues was observed.
Matrices listed below were spiked with certain level of recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 98-105 | 102 |
EDTA plasma(n=5) | 89-96 | 92 |
heparin plasma(n=5) | 95-103 | 98 |
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10%>10%>Inter-Assay: CV<12%>12%>
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 83-92% | 95-103% | 78-91% | 84-98% |
EDTA plasma(n=5) | 84-102% | 87-101% | 95-105% | 95-102% |
heparin plasma(n=5) | 87-98% | 80-97% | 95-103% | 92-105% |
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
1. Prepare all reagents, samples and standards;2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;4. Aspirate and wash 3 times;5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;6. Aspirate and wash 5 times;7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;8. Read RLU value immediately.
The microplate provided in this kit has been pre-coated with an antibody specific to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) level in the sample or standard.;
ELISA / CLIA Experiment Service
Single-component Reagents of Assay KitLysis Buffer Specific for ELISA / CLIAQuality Control of ELISA / CLIACLIA Kit Customized ServiceDisease Model Customized ServiceSerums Customized ServiceTGFB1 Activation ReagentReal Time PCR Experimental ServiceStreptavidin
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
APA040Hu01 | Active Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | Cell culture; Activity Assays. |
RPA040Hu02 | Recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA040Hu01 | Recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | Positive Control; Immunogen; SDS-PAGE; WB. |
APA040Hu02 | Active Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | Cell culture; Activity Assays. |
PAA040Hu01 | Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | WB; IHC; ICC; IP. |
PAA040Hu02 | Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | WB; IHC; ICC; IP. |
LAA040Hu81 | FITC-Linked Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | WB; IHC; ICC; IF. |
LAA040Hu71 | Biotin-Linked Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | WB; IHC; ICC. |
MAA040Hu22 | Monoclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | WB; IHC; ICC; IP. |
SEA040Hu | ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA040Hu | CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | Chemiluminescent immunoassay for Antigen Detection. |
KSA040Hu01 | ELISA Kit DIY Materials for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) | Main materials for "Do It (ELISA Kit) Yourself". |
在20mM Tris,150mM NaCl(pH8.0)中复溶至0.1-1.0 mg / mL的浓度。不要涡旋。
避免重复冷冻/解冻循环。在2-8°C下保存一个月。分装并在-80°C下存储12个月。
热稳定性由损失率描述。损失率通过加速热降解试验确定,即将蛋白质在37°C下孵育48h,没有观察到明显的降解和沉淀。在适当的存储条件下,有效期内的丢失率小于5%。